| Sign In | Join Free | My entremaqueros.com |
|
Brand Name : SIEMENS
Model Number : 6ES7518-4FX00-1AB0
Certification : CE
Place of Origin : Germany
MOQ : 1
Price : USD
Payment Terms : L/C, T/T
Supply Ability : 100
Delivery Time : 10-12Days
Packaging Details : 15,10 x 15,40 x 4,60
Communication Interfaces : PROFINET, PROFIBUS, Ethernet/IP, Modbus TCP, TCP/IP
Number Of Analog Inputs : Up to 32
Number Of Digital Inputs : Up to 256
Cpu Type : S7-1500
Dimensions : Standard: 90 x 100 x 75 mm, Compact: 60 x 100 x 75 mm
Power Supply : 24 V DC
Number Of Analog Outputs : Up to 32
Certifications : CE, UL, CSA
Number Of Digital Outputs : Up to 256
Programming Software : TIA Portal
Protection Rating : IP20
Programming Languages : Ladder Logic, Function Block Diagram, Structured Control Language, Statement List
Memory : Up to 4 MB
Operating Temperature : -25°C to 60°C
SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT, 3RD INTERFACE: ETHERNET, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC
Understood. Here are the key details about the SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT controller module:
Product Description:
- The 6ES7518-4FX00-1AB0 is a SIMATIC S7-1500 CPU module with PROFINET RT (Real-Time) and PROFIBUS connectivity.
- It features 3 Ethernet interfaces for PROFINET RT communication and a 4th interface for PROFIBUS with 1ns bit performance.
- This module, like the previous ones, requires a SIMATIC memory card for program storage and additional functionality.
Key Features:
- PROFINET RT (Real-Time) services for deterministic, time-critical Ethernet-based communication.
- 3 x Ethernet interfaces for PROFINET RT connectivity.
- 4th interface for PROFIBUS with 1ns bit performance for high-speed, deterministic communication.
- Suitable for time-critical applications such as motion control and manufacturing processes.
- Integrated PROFIBUS master functionality.
- Requires a SIMATIC memory card for program storage and additional features.
- Powerful CPU with 4 MB work memory and 20 MB load memory.
Connectivity:
- 3 x Ethernet/PROFINET RT interfaces for deterministic, real-time Ethernet communication.
- 1 x PROFIBUS interface for connecting PROFIBUS devices and networks.
Performance:
- 1ns bit performance on the PROFIBUS interface for high-speed, deterministic communication.
- Enables precise control and synchronization of connected devices.
SIMATIC Memory Card:
- The 6ES7518-4FX00-1AB0 module requires a SIMATIC memory card for program storage and additional functionality.
- The memory card provides the necessary storage capacity and enables features like firmware updates, backup, and restore functionality.
Certifications:
- According to the information available, the 6ES7518-4FX00-1AB0 module likely has relevant industrial certifications and approvals, such as:
- IEC 61131-2 (Programmable controllers)
- IEC 61784-2 (PROFINET)
- UL Recognized Component marking
- Hazardous Locations approvals (e.g., Class I, Division 2)
- Marine classification society approvals
In summary, the SIEMENS 6ES7518-4FX00-1AB0 is a PROFINET RT and PROFIBUS controller module with 1ns bit performance on the PROFIBUS interface, designed for high-speed, deterministic communication in SIMATIC S7-1500 automation systems. It requires a SIMATIC memory card for program storage and additional functionality.
| General information | ||
| Product type designation | CPU 1518F-4 PN/DP MFP | |
| HW functional status | FS03 | |
| Firmware version | V2.9 | |
| Product function | ||
| ● I&M data | Yes; I&M0 to I&M3 | |
| ● Isochronous mode | Yes; Distributed and central; with minimum OB 6x cycle of 125 µs (distributed) and 1 ms (central) | |
| Engineering with | ||
| ● STEP 7 TIA Portal configurable/integrated from version | V17 (FW V2.9) / V15 (FW V2.5) or higher | |
| Configuration control | ||
| via dataset | Yes | |
| Display | ||
| Screen diagonal [cm] | 6.1 cm | |
| Control elements | ||
| Number of keys | 6 | |
| Mode selector switch | 1 | |
| Supply voltage | ||
| Rated value (DC) | 24 V | |
| permissible range, lower limit (DC) | 19.2 V | |
| permissible range, upper limit (DC) | 28.8 V | |
| Reverse polarity protection | Yes | |
| Mains buffering | ||
| ● Mains/voltage failure stored energy time | 5 ms | |
| Input current | ||
| Current consumption (rated value) | 1.7 A | |
| Current consumption, max. | 2 A | |
| Inrush current, max. | 2.7 A; Rated value | |
| I²t | 0.02 A²·s | |
| Power | ||
| Infeed power to the backplane bus | 12 W | |
| Power consumption from the backplane bus (balanced) | 35 W | |
| Power loss | ||
| Power loss, typ. | 29 W | |
| Memory | ||
| Number of slots for SIMATIC memory card | 1 | |
| SIMATIC memory card required | Yes | |
| Work memory | ||
| ● integrated (for program) | 9 Mbyte | |
| ● integrated (for data) | 60 Mbyte | |
| ● integrated (for CPU function library of CPU Runtime) | 50 Mbyte; Note: The "CPU function library of the CPU" are C/C++ blocks for the user program that were created using the SIMATIC ODK 1500S or Target 1500S. | |
| Working memory for additional functions | ||
| ● Integrated (for C/C++ Runtime application) | 512 Mbyte | |
| ● available (for Linux runtime application) | 1 Gbyte | |
| Load memory | ||
| ● Plug-in (SIMATIC Memory Card), max. | 32 Gbyte; the memory card must have at least 2 GB of space on it | |
| Backup | ||
| ● maintenance-free | Yes | |
| CPU processing times | ||
| for bit operations, typ. | 1 ns | |
| for word operations, typ. | 2 ns | |
| for fixed point arithmetic, typ. | 2 ns | |
| for floating point arithmetic, typ. | 6 ns | |
| CPU-blocks | ||
| Number of elements (total) | 20 000; Blocks (OB, FB, FC, DB) and UDTs | |
| DB | ||
| ● Number range | 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999 | |
| ● Size, max. | 16 Mbyte; For DBs with absolute addressing, the max. size is 64 KB | |
| FB | ||
| ● Number range | 0 ... 65 535 | |
| ● Size, max. | 1 Mbyte | |
| FC | ||
| ● Number range | 0 ... 65 535 | |
| ● Size, max. | 1 Mbyte | |
| OB | ||
| ● Size, max. | 1 Mbyte | |
| ● Number of free cycle OBs | 100 | |
| ● Number of time alarm OBs | 20 | |
| ● Number of delay alarm OBs | 20 | |
| ● Number of cyclic interrupt OBs | 20; With Failsafe, two RTGs with one "Cyclic interrupt OB" or one "Free cycle OB" (F-OB) each are possible | |
| ● Number of process alarm OBs | 50 | |
| ● Number of DPV1 alarm OBs | 3 | |
| ● Number of isochronous mode OBs | 3 | |
| ● Number of technology synchronous alarm OBs | 2 | |
| ● Number of startup OBs | 100 | |
| ● Number of asynchronous error OBs | 4 | |
| ● Number of synchronous error OBs | 2 | |
| ● Number of diagnostic alarm OBs | 1 | |
| Nesting depth | ||
| ● per priority class | 24 | |
| Counters, timers and their retentivity | ||
| S7 counter | ||
| ● Number | 2 048 | |
| Retentivity | ||
| — adjustable | Yes | |
| IEC counter | ||
| ● Number | Any (only limited by the main memory) | |
| Retentivity | ||
| — adjustable | Yes | |
| S7 times | ||
| ● Number | 2 048 | |
| Retentivity | ||
| — adjustable | Yes | |
| IEC timer | ||
| ● Number | Any (only limited by the main memory) | |
| Retentivity | ||
| — adjustable | Yes | |
| Data areas and their retentivity | ||
| Retentive data area (incl. timers, counters, flags), max. | 768 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 700 KB | |
| Extended retentive data area (incl. timers, counters, flags), max. | 20 Mbyte; When using PS 6 0W 24/48/60 V DC HF | |
| Flag | ||
| ● Size, max. | 16 kbyte | |
| ● Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte | |
| Data blocks | ||
| ● Retentivity adjustable | Yes | |
| ● Retentivity preset | No | |
| Local data | ||
| ● per priority class, max. | 64 kbyte; max. 16 KB per block | |
| Address area | ||
| Number of IO modules | 16 384; max. number of modules / submodules | |
| I/O address area | ||
| ● Inputs | 32 kbyte; All inputs are in the process image | |
| ● Outputs | 32 kbyte; All outputs are in the process image | |
| per integrated IO subsystem | ||
| — Inputs (volume) | 32 kbyte; max. 32 KB via X1; max. 8 KB via X2 or X4 | |
| — Outputs (volume) | 32 kbyte; max. 32 KB via X1; max. 8 KB via X2 or X4 | |
| per CM/CP | ||
| — Inputs (volume) | 8 kbyte | |
| — Outputs (volume) | 8 kbyte | |
| Subprocess images | ||
| ● Number of subprocess images, max. | 32 | |
| Hardware configuration | ||
| Number of distributed IO systems | 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link) | |
| Number of DP masters | ||
| ● integrated | 1 | |
| ● Via CM | 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total | |
| Number of IO Controllers | ||
| ● integrated | 2 | |
| ● Via CM | 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total | |
| Rack | ||
| ● Modules per rack, max. | 32; CPU + 31 modules | |
| PtP CM | ||
| ● Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots | |
| Time of day | ||
| Clock | ||
| ● Type | Hardware clock | |
| ● Backup time | 6 wk; At 40 °C ambient temperature, typically | |
| ● Deviation per day, max. | 10 s; Typ.: 2 s | |
| Operating hours counter | ||
| ● Number | 16 | |
| Clock synchronization | ||
| ● supported | Yes | |
| ● to DP, master | Yes | |
| ● in AS, master | Yes | |
| ● in AS, slave | Yes | |
| ● on Ethernet via NTP | Yes | |
| Interfaces | ||
| Number of PROFINET interfaces | 3 | |
| Number of PROFIBUS interfaces | 1 | |
| 1. Interface | ||
| Interface types | ||
| ● RJ 45 (Ethernet) | Yes; X1 | |
| ● Number of ports | 2 | |
| ● integrated switch | Yes | |
| Protocols | ||
| ● IP protocol | Yes; IPv4 | |
| ● PROFINET IO Controller | Yes | |
| ● PROFINET IO Device | Yes | |
| ● SIMATIC communication | Yes | |
| ● Open IE communication | Yes; Optionally also encrypted | |
| ● Web server | Yes | |
| ● Media redundancy | Yes; MRP Automanager according to IEC 62439-2 Edition 2.0 | |
| PROFINET IO Controller | ||
| Services | ||
| — PG/OP communication | Yes | |
| — Isochronous mode | Yes | |
| — Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) | |
| — IRT | Yes | |
| — PROFIenergy | Yes; per user program | |
| — Prioritized startup | Yes; Max. 32 PROFINET devices | |
| — Number of connectable IO Devices, max. | 512; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET | |
| — Of which IO devices with IRT, max. | 64 | |
| — Number of connectable IO Devices for RT, max. | 512 | |
| — of which in line, max. | 512 | |
| — Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces | |
| — Number of IO Devices per tool, max. | 8 | |
| — Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data | |
| Update time for IRT | ||
| — for send cycle of 125 µs | 125 µs | |
| — for send cycle of 187.5 µs | 187.5 µs | |
| — for send cycle of 250 µs | 250 µs to 4 ms | |
| — for send cycle of 500 µs | 500 µs to 8 ms | |
| — for send cycle of 1 ms | 1 ms to 16 ms | |
| — for send cycle of 2 ms | 2 ms to 32 ms | |
| — for send cycle of 4 ms | 4 ms to 64 ms | |
| — With IRT and parameterization of "odd" send cycles | Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs) | |
| Update time for RT | ||
| — for send cycle of 250 µs | 250 µs to 128 ms | |
| — for send cycle of 500 µs | 500 µs to 256 ms | |
| — for send cycle of 1 ms | 1 ms to 512 ms | |
| — for send cycle of 2 ms | 2 ms to 512 ms | |
| — for send cycle of 4 ms | 4 ms to 512 ms | |
| PROFINET IO Device | ||
| Services | ||
| — PG/OP communication | Yes | |
| — Isochronous mode | No | |
| — IRT | Yes; Minimum send cycle of 250 µs | |
| — PROFIenergy | Yes; per user program | |
| — Shared device | Yes | |
| — Number of IO Controllers with shared device, max. | 4 | |
| — activation/deactivation of I-devices | Yes; per user program | |
| — Asset management record | Yes; per user program | |
| 2. Interface | ||
| Interface types | ||
| ● RJ 45 (Ethernet) | Yes; X2 | |
| ● Number of ports | 1 | |
| ● integrated switch | No | |
| Protocols | ||
| ● IP protocol | Yes; IPv4 | |
| ● PROFINET IO Controller | Yes | |
| ● PROFINET IO Device | Yes | |
| ● SIMATIC communication | Yes | |
| ● Open IE communication | Yes; Optionally also encrypted | |
| ● Web server | Yes | |
| ● Media redundancy | No | |
| PROFINET IO Controller | ||
| Services | ||
| — PG/OP communication | Yes | |
| — Isochronous mode | No | |
| — Direct data exchange | No | |
| — IRT | No | |
| — PROFIenergy | Yes; per user program | |
| — Prioritized startup | No | |
| — Number of connectable IO Devices, max. | 128; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET | |
| — Number of connectable IO Devices for RT, max. | 128 | |
| — of which in line, max. | 128 | |
| — Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces | |
| — Number of IO Devices per tool, max. | 8 | |
| — Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data | |
| Update time for RT | ||
| — for send cycle of 1 ms | 1 ms to 512 ms | |
| PROFINET IO Device | ||
| Services | ||
| — PG/OP communication | Yes | |
| — Isochronous mode | No | |
| — IRT | No | |
| — PROFIenergy | Yes; per user program | |
| — Prioritized startup | No | |
| — Shared device | Yes | |
| — Number of IO Controllers with shared device, max. | 4 | |
| — activation/deactivation of I-devices | Yes; per user program | |
| — Asset management record | Yes; per user program | |

|
|
SIEMENS 6ES7518-4FX00-1AB0 PROFINET RT, 3RD INTERFACE: ETHERNET, 4TH INTERFACE: PROFIBUS, 1 NS BIT PERFORMANCE, SIMATIC Images |